Standalone BTS Site Monitor

Monitor critical BTS site parameters — power failure, generator status, fire, temperature, battery — and send SMS alerts directly to field technicians and supervisors. No NOC/TOC required. Suitable for a single site or hundreds.

View Specifications
Spaceage Standalone BTS Site Monitor

Features & Specifications

System Specifications
Alarm Inputs4 NO/NC voltage-free contacts
SMS RecipientsUp to 4 people per alarm event
Operating Supply48V DC ±15%
GSM HardwareInbuilt GSM modem (SIM provided by customer)
Alarm Clear SMSAutomatic when alarm condition clears
ConfigurationWindows-based software — configurable remotely
ScalabilitySuitable for 1 site or hundreds of sites
Escalation Matrix
  • Alarm triggers — immediate SMS to Technician
  • If unresolved after defined time (e.g. 30 min) — SMS to Supervisor
  • Further escalation to higher management if needed
  • Alarm clear SMS sent to all recipients automatically
  • Escalation times user-defined via Windows software
  • SIM card from any cellular operator — flexible

Where It's Deployed

Remote BTS Sites

Sites not connected to a NOC/TOC still need proactive alerting — this system provides it via any GSM network.

Small Infra Operators

Infrastructure providers with fewer sites who cannot justify a full NOC/TOC deployment benefit from this cost-effective alternative.

SLA Assurance

Field teams are notified instantly — ensuring SLA response times are met without centralised monitoring infrastructure.

NOC/TOC Supplement

Can work in parallel with or as a backup to existing NOC/TOC systems, extending coverage to disconnected sites.

Frequently Asked Questions

The Standalone Site Monitor sends SMS directly from the site to field technicians and supervisors — no central monitoring centre needed. It includes an escalation matrix: the technician is alerted immediately, and if unresolved after a defined time, the supervisor is automatically notified. Perfect for sites not connected to a NOC/TOC.

The system monitors 4 NO/NC voltage-free alarm contacts. Typical connections: EB (electricity board) failure, Genset failure, Fire alarm, High temperature, and Battery low. Any device with a voltage-free NO/NC output can be connected.

Alarm triggers → immediate SMS to technician. If alarm remains active beyond user-defined time (e.g. 30 minutes) → second SMS to supervisor. Alarm clear SMS is sent automatically to all recipients when the condition resolves. Phone numbers and escalation times configured via Windows software, remotely.

Monitor Every BTS Site — No NOC/TOC Needed

Works with any GSM network. Scalable from 1 site to hundreds. Contact us for a quote.