Genset Optimizer / BTS DG Controller

Microprocessor-based controller that starts your diesel generator only when genuinely needed — based on shelter temperature or battery voltage. Substantially reduces fuel consumption at unmanned BTS sites.

View Specifications
Spaceage Genset Optimizer BTS DG Controller

Two Control Logics, One Smart Controller

Temperature-Based Control

When AC mains fails and the shelter heats up:

Temp > AC ON threshold → Generator starts, AC compressor runs
Temp < AC OFF threshold → Generator stops
AC mains restored → Unit bypasses itself automatically
Battery Voltage-Based Control

During extended mains outage or cold weather:

Voltage < CHARGE ON level → Generator starts
Voltage ≥ CHARGE OFF level → Generator stops
Min ON time → Overrideable by user for operational needs

Specifications & Operation Logic

Unit Specifications
DisplayBacklit LCD for parameter configuration & monitoring
Dimensions12" × 10" × 3.5" (wall mountable)
Internal BatteryIn-built battery with charger for uninterrupted operation
AC Mains BypassAutomatic self-bypass when AC mains is available
Max Genset RuntimeConfigurable maximum run time even if limits not reached
Operation Logic Summary
  • Check AC mains — if available, do nothing
  • Check temperature — if above limit, start generator
  • Keep generator ON until temperature reaches lower limit
  • If temperature OK but battery low, start generator
  • Continuously monitor both voltage and temperature
  • Stop generator when both parameters are within range
  • Stop genset after maximum runtime regardless of parameters

Ideal For

Unmanned BTS Sites

Saves significant diesel cost at remote tower sites where the AC should only run when cooling is genuinely needed.

Off-Grid Rural Sites

Sites with irregular grid power rely heavily on genset — optimizer dramatically reduces per-site fuel expenditure.

Battery Life Extension

By avoiding unnecessary discharge cycles, the optimizer extends battery bank life and reduces replacement costs.

OPEX Reduction

Telecom tower companies deploying across thousands of sites achieve substantial OPEX savings per site per year.

Frequently Asked Questions

The optimizer keeps the diesel generator OFF when AC mains is available. When mains fails, it monitors shelter temperature and battery voltage. The generator only starts when temperature exceeds the 'AC ON' threshold or battery drops below 'CHARGE ON' voltage — not continuously. It stops automatically once both parameters return to normal.

If shelter temperature exceeds the preset 'AC ON' threshold, the generator starts and runs until temperature falls to the 'AC OFF' limit. Thresholds are user-configurable via the front-panel LCD display, so the AC compressor only runs when genuinely needed.

When battery voltage drops below the 'CHARGE ON' level, the genset starts and runs until voltage reaches the 'CHARGE OFF' point. This reduces unnecessary charge cycles and extends battery lifespan. Users can also set a minimum genset ON time for operational flexibility.